Posted on Jan 30th 2021
What is a Condensate pipe?
As evident from the name, a condensate pipe is used to drain the excess water condensed in your boiler. Since this condensate is mildly acidic due to dissolved gases, it is needed to drain through a PVC pipe because it might corrode a metal pipe.
So you can quickly figure out which one is the condensate pipe as it is only a nonmetal pipe coming out of the boiler.
Common reasons for the leakage:
A frozen condensate pipe is the biggest headache, but some other sudden issues can happen. Some of you may have just confronted them; others have not. Whatever the case is, you will discover the laid out over here profoundly valuable.
The heat exchanger is broken:
The condensate trap and line come straight out of the heat exchanger, which implies that if it breaks or pinholes, it will cause the framework or mains water to drain into the condensate pipe. What may prompt the condensate pipe spilling is if the boiling water causes the line joints to fail in one way or another.
Solution: The only way to eliminate this issue is to change your change exchanger. We realize that this can cost you a great deal, so having an expert assess your heat exchanger will significantly increase its life.
Joints leak of condensate pipe:
This can if the condensate pipe installation was not done correctly like:
- The joints are not appropriately fixed: no PVC pipe concrete was utilized for that reason.
- Incorrect line and fittings are utilized: the solitary lines used to drain the condensate are PVC or ABS. As we previously referenced, some other metal lines would erode.
- If the fittings have a metal substance (like grab rings), they will rust too.
Solution: If the issue is missing PVC pipe concrete to seal the fitting line, you can get it from your nearby home store.
The condensate trap is blocked:
The condensate trap captures the condensate produced in the boilers and discharges it afterward. If you hear gurgling noise from the boiler, you might be having this issue. The flue gases also make some noise. Debris from the heat exchanger can also end up in the sump and cause the condensate trap's blocking. Consequently, this will stop the flow of condensate and control your boiler from leaking.
Solution: Condensate trap can be cleaned very quickly, and it is a quick process you can easily. But you can also call for an expert to do this job.
Just like the heat exchanger, the condenser should be inspected regularly to avoid any inconvenience.